R Chamber Specifications
"R" chambers are small reach-in chambers, half of which have been modified to provide high light intensities. Refer to the table below for specific information on the size and capabilities of these chambers.
|
Chamber dimensions |
1.2 m wide x .91 m deep x 1 m tall |
|
Temperature range |
Lighted: 12° - 35° C (28° - 35° C in high light chambers) Dark: 2° - 30° C |
|
Humidity range |
ambient (no humidity control) |
|
CO2 range |
200 - 1000 ppm |
|
Maximum light intensity |
350 micromols m-2 s-1 PAR (1000 in high light chambers) |
|
Lamp mixture |
fluorescent + incandescent (metal halide + tungsten halogen in high light chambers) |
|
Number of light levels |
1 (all lamps on) plus incandescent (or halogen) lamps only |
|
Controllers |
Time clocks |
|
Number of chambers |
Standard light chambers: 10 High light chambers: 10 |